                            rechargeable lead acid battery 12V2.6ah

                            rechargeable lead acid battery 12V2.6ah

                            rechargeable lead acid battery 12V2.6ah

                            rechargeable lead acid battery 12V2.6ah

                            rechargeable lead acid battery 12V2.6ah

rechargeable lead acid battery 12V2.6ah

rechargeable lead acid battery 12V2.6ah,CSSB,SAKO,UNITY,Electrical Equipment & Supplies,Batteries,Storage Batteries
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
CSSB,SAKO,UNITY
Model Number:
12V2.6AH
Nominal Capacity:
12V
Usage:
UPS
Sealed Type:
Sealed
Maintenance Type:
Free
Weight:
0.84
Material:
ABS
Certificate:
CE,ROHS
Warranty time:
1 Year
OEM:
Available
Size:
70*47*98*102
Voltage:
12V
Supply Ability
Supply Ability:
100000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
Standard export plastic bag, terminal sheath ,carton,pallet
Port
shenzhen yantian

Specifications

solar street lights VRLA storage battery 12V2.6AH 
1.low self-discharge 
2.With CE certificate

Application

Maintenance free storage battery 12V2.6AH is widely used among the field of UPS,telecommunication system,power station system,railway system,emergency lighting system,automatic control system,marine equipment,alarm system for fire protection,security,solar wind powered systems,portable instruments,medica equipment, electric instruments,electric vehicles,computer backup power ,etc. all our products are CE,ROHS approved

 

 

 Product features

1.Low self-discharge:At theambient temperature 25,the rate of self-discharge less than 1.8% after 28 days storage.
2.Wide operating temperature range:Shensong battery can charge by 0~40
,discharge by -20~+55 and store by-15~+50
3.Good sealing capability:No pollution and corrosion, which ensures Shensong battery operate sately and efficiently in side and vertical position.The sealed construction can combine the generated gas to water,and noneed to add water or check their specific gravity during the life of Shensong batteries.
4.Good electric conductivity:Adopting red copper with silver plated patent terminal canmake batteries discharge with high current.

  

 

Model No.

12V2.6AH

Nominal Voltage

12V

Dimension(mm)

Length

Width

Height

Total Height

70

47

98

102

Approx. Weight

0.84kg

container material

ABS

Roted capacity

20hr,1.8V

10hr,1.75V

5hr,1.75V

3hr,1.75

1hr,1.67V

2.80Ah/0.140A

2.60Ah/0.260A

2.35Ah/0.470A

2.06Ah/0.685A

1.70Ah/1.70A

Max discharge current

42A(5s)

Internal resistance

Approx. 55mΩ

Operating temperature range

 Discharge

Charge

Storage

-15°C~55°C

 0°C~40°C

-15°C~50°C

Nominal operating temperature

25°C±3°C

Cyclic charging voltage

Initial charging current less than 0.84A voltage                                                                        14.4-15.0V~7.5V at 25°C temp.coefficient -30mv/°C

Standby use

No limit on Initial charging current voltage 
13.5V~13.8V at 25°C temp.coefficint-20mv/°C     

Capacity affected by temperature 

40°C

25°C  

0°C  

103%

100%   

86%  

 

 

 

 

  

 

 

Notice

1. According to the requirement of application and design to choose battery model,characteristics and mounting method.

 

2. Avoid mixing use of the batteries with different capacity,manufacturers,characteristics and models.

 

3. It is recommended to charge the battery using the method of constant voltage-limited current.Under the ambient temperature 25 
:for standby use,the charging voltage is2.23-2.30V/cell,and no limit on the maximum current;for cycle use, the charging voltage is 2.40-2.50V/cell,average charging voltage:2.35-2.4V/cell.The maximum current is 0.3C10(C10 is the rated capacity of discharging at 10 hours rate).

 

4. During operating,please sdjust the battery charging voltage according to the ambient temperature. The temperature compensation coefficient is -3mV/ cell for standby use ,i.e. the temperature increases 1 
,the charging voltage decreases 3mV/cell.The temperature compensation coefficient is -5mV/ 
cell for cycle use;average charging time:-4mV/ cell.

 

5. Do not charge the battery in a sealed container or in upside down position.It is recommended to charge thebattery in a well ventilated place.

 

6. Do not charge the battery near a heater,or the place where heat accumulation may occur.Do not charge the battery in a place where there is direct sunshine.

 

7. Never have the batteries deposited with organic solvents to prevent the container from being out of shape or corrosion.

 

8. Battery should never be stored in a discharge state for a long period of time ,please recharge the battery after discharge to keep the capacity.During operating,do not over discharge to avoid the plates severe sulphation which affects the service life and capacity.

 

9. Do not over charge the battery ,as the safety vent opens constantly,which will cause the loss of water,finally shorten the service life of battery.

 

10. Red color stand for positive,and black for negative.Please connect the pole of batteries correctly.

 

11. keep the whole battery clean and connection strong.Avoid the damage due to the loose connection.

 

12. Do not disassemble or throw the battery into fire,against the explosion.