• Phone

    86-0755-28994210

  • Address

    No. 2, Xinan Road, Shigu Village, Tangxia Town, Dongguan, Guangdong, China (Mainland)

  • E-mail

    k@waimaotong.com


                            12V28AH ups rechargeable lead acid battery

                            12V28AH ups rechargeable lead acid battery

12V28AH ups rechargeable lead acid battery

12V28AH ups rechargeable lead acid battery,CSSB,SAKO,UNITY,Electrical Equipment & Supplies,Batteries,Storage Batteries
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
CSSB,SAKO,UNITY
Model Number:
6-FM-28
Nominal Capacity:
28AH
Usage:
UPS
Sealed Type:
Sealed
Maintenance Type:
Free
Weight:
8.0kg
Material:
ABS
Certificate:
CE,ROHS
Warranty time:
1 Year
OEM:
Available
ODM:
Available
Color:
Black
Lead quality:
99.99%
MSDS:
Available
Size:
175*166*125*125
Voltage:
12V
Supply Ability
Supply Ability:
10000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
Standard export plastic bag, terminal sheath ,carton,pallet
Port
shenzhen SHEKOU
Lead Time :
7-15days

Specifications

 

12V28Ah sealed lead acid battery 
Nominal Voltage 12V
Rated Capacity( 20 hour rate ) 28Ah
Dimensions(Length*Width*Height*Total height) 175*166*125*125MM
Weight Approx 8.0KG
Capacity
25℃(77°F)
20 Hour Rate(1.4A)28AH
10 Hour Rate(2.564A)25.6AH
5 Hour Rate(4.76A)23.8AH
1 Hour Rate(16.8A)1.68AH
Internal ResistanceFull Charged Battery 25℃(77°F)14mΩ
Capacity Affected By Temperature40°C(104°F)102%
25°C(77°F)100%
0°C(32°F)85%
-15°C(5°F)65%
Self-Discharge at
 25°C(77°F)
Capacity after 3 Month Storage91%
Capacity after 6 Month Storage82%
Capacity after 12 Month Storage64%
Charge (Constant Voltage) 25°C(77°F)FloatNo limit Initial charging current
voltage13.50-13.80V
CycleInitial Charging Current Less than 8.4A
Voltage 14.40-15V
Terminal Typelead
Warranty1 Years
ColorBlack, Gray
Container Material 
CertificateCE; ISO9001; 

 


  


Application

Maintenance free storage battery 12V26Ah is widely used among the field of UPS,telecommunication system,power station system,railway system,emergency lighting system,automatic control system,marine equipment,alarm system for fire protection,security,solar wind powered systems,portable instruments,medica equipment, electric instruments,electric vehicles,computer backup power ,etc. all our products are CE,ROHS approved

 

 

 

 Product features

1. Low self-discharge:At theambient temperature 25,the rate of self-discharge less than 1.8% after 28 days storage.
2. Wide operating temperature range:Shensong battery can charge by 0~40
,discharge by -20~+55 and store by-15~+50
3. Good sealing capability:No pollution and corrosion, which ensures Shensong battery operate sately and efficiently in side and vertical position.The sealed construction can combine the generated gas to water,and noneed to add water or check their specific gravity during the life of Shensong batteries.
4. Good electric conductivity:Adopting red copper with silver plated patent terminal canmake batteries discharge with high current.

 

 

Notice

1. According to the requirement of application and design to choose battery model,characteristics and mounting method.

 

2. Avoid mixing use of the batteries with different capacity,manufacturers,characteristics and models.

 

3. It is recommended to charge the battery using the method of constant voltage-limited current.Under the ambient temperature 25 
:for standby use,the charging voltage is2.23-2.30V/cell,and no limit on the maximum current;for cycle use, the charging voltage is 2.40-2.50V/cell,average charging voltage:2.35-2.4V/cell.The maximum current is 0.3C10(C10 is the rated capacity of discharging at 10 hours rate).

 

4. During operating,please sdjust the battery charging voltage according to the ambient temperature. The temperature compensation coefficient is -3mV/ cell for standby use ,i.e. the temperature increases 1 ,the charging voltage decreases 3mV/cell.The temperature compensation coefficient is -5mV/ cell for cycle use;average charging time:-4mV/ cell.

 

5. Do not charge the battery in a sealed container or in upside down position.It is recommended to charge thebattery in a well ventilated place.

 

6. Do not charge the battery near a heater,or the place where heat accumulation may occur.Do not charge the battery in a place where there is direct sunshine.

 

7. Never have the batteries deposited with organic solvents to prevent the container from being out of shape or corrosion.

 

8. Battery should never be stored in a discharge state for a long period of time ,please recharge the battery after discharge to keep the capacity.During operating,do not over discharge to avoid the plates severe sulphation which affects the service life and capacity.

 

9. Do not over charge the battery ,as the safety vent opens constantly,which will cause the loss of water,finally shorten the service life of battery.

 

10. Red color stand for positive,and black for negative.Please connect the pole of batteries correctly.

 

11. keep the whole battery clean and connection strong.Avoid the damage due to the loose connection.

 

12. Do not disassemble or throw the battery into fire,against the explosion.